Weatherproof Box, attached to pole or board Remove wire from 200-amp breaker or main lugs 60-amp Breaker W/ retaining clip # 12 Color, White & Green. White & Green go to Neutral Bus Black wire goes to 20-amp single pole Breaker 30-amp, 110 volt R. V. receptacle 20-amp GFCI receptacle Black Wire goes to breaker Install # 6 copper hot wires from meter to 60-amp breaker # 8 Neutral Wire W/ white tape at each end Neutral Bus Install Green Bonding Screw 60 Main
![]()
![]()

![]()
![]()
![]()
![]()
![]()
![]()
![]()

![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
R. V.
PANEL WIRING
Meter Can
Green or Bare wire White wire 20-amp breaker 30-amp breaker #10 Color, White & Green. White & Green go to Neutral Bus. Black wire goes to 30-amp single pole breaker Nipple from panel to receptacle box, Galvanized or PVC
![]()
![]()
![]()